Transformer Oil BDV Tester

  • OVT-80T   Insulation Oil Tester

    OVT-80T Insulation Oil Tester

    The OVT-80T Insulating Oil Tester, developed and manufactured by HV HIPOT in accordance with relevant standards such as IEC 60156, ASTM D877, and ASTM D1816, is a professional instrument for testing the dielectric strength of insulating oils and evaluating their quality and performance. A single-chip microcomputer controls the internal boost system, applying an electric field and detecting the breakdown voltage of the insulating oil, providing a reliable basis for evaluating insulating oil quality. 

  • OVT-80K    Insulation Oil Tester

    OVT-80K Insulation Oil Tester

    OVT-80K Insulating Oil Dielectric Strength Tester, developed and manufactured by HV HIPOT in accordance with relevant standards such as IEC 60156, ASTM D877, and ASTM D1816, is a professional instrument for testing the dielectric strength of insulating oils and evaluating their quality and performance.

  • GDOT-80A Insulation Oil Tester

    GDOT-80A Insulation Oil Tester

    Please read the operation manual carefully before operating.
    Please check if the tester is well connected to earth before testing.
    It is forbidden to move or lift the testing cover in the process of testing to avoid injury by high voltage. Power must be off before replace sampling oil.

  • GDOT-80C Insulation Oil Breakdown Tester 80kV

    GDOT-80C Insulation Oil Breakdown Tester 80kV

    There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation. 

  • GDOT-100C Insulation Oil Breakdown Tester 100kV

    GDOT-100C Insulation Oil Breakdown Tester 100kV

    GDOT-100C Insulation Oil Breakdown Tester is fully digital industrial instrument with microcomputer control. It has the features of high accuracy and strong anti-interference ability.

  • GDOT-100D 100kV Insulation Oil Tester

    GDOT-100D 100kV Insulation Oil Tester

    In power system, railway system and large petrochemical industrial enterprises all have  a lot of electrical equipment, its internal insulation is mostly oil-filled insulation type.

  • GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation. The dielectric strength of insulating oil is a mandatory routine test. In order to meet the needs of the market, our company developed and produced a series of dielectric oil dielectric strength testers according to the national standard GB/T507-2002(IEC156), the standard DL429.9-91 and the latest power industry standard DL/T846.7-2004. This instrument takes the single-chip microcomputer as the core, realizes all the automation of the test, has high measurement precision, greatly improves the work efficiency, and greatly reduces the labor intensity of the staff. At the same time, the instrument has a compact appearance and is convenient to carry.

  • GDOT-3B 100kV Three Cups Insulation Oil Breakdown Voltage (BDV) Tester

    GDOT-3B 100kV Three Cups Insulation Oil Breakdown Voltage (BDV) Tester

    In the power system and factories, mines, enterprises have a large number of electrical equipment, its internal insulation are oil-filled insulation. The dielectric strength test of the insulating oil is a routine test must be measured.

    In order to adapt to the needs of the rapid development of the power industry, the new version GDOT-3B Insulation oil BDV tester increase the standards and methods of selection and other content, simplify the user’s operation, to facilitate the application of the user for different conditions of use. This product is based on the new test protocol DL/T 596-2005 and the corresponding national standard GB/T 507-2002 and DL/T 429.9-91 design and manufacture, the use of micro-single-chip computer control, electromechanical integration of all automation, high measurement accuracy, greatly improving the efficiency of the work, but also greatly reduces the staff’s labor intensity.

     

     

  • GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester

    GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester

    GDOT-3C 80kV 3 Cups Insulation Oil Breakdown Voltage Tester is fully digital industrial instrument with microcomputer control. It has the features of high accuracy and strong anti-interference ability.

Send your message to us:

Write your message here and send it to us