GDCR9300 High Precision Wireless Clamp Multimeter for Electrical Testing
| Function | Measurement of high voltage AC current, low voltage AC current, on-line monitoring AC current. |
| Power Supply | DC6V Alkaline Dry Battery (1.5V AAA X4pcs) |
| Test Mode | Clamp CT |
| Transmission Mode | 433MHz wireless transmission, distance about 100m |
| Display Mode | 4 digital LCD display, backlight function, suitable for dark place. |
| LCD Dimension | 47mm*28.5mm |
| Meter Dimension | Detector: 210mm*246mm*45mm
Receiver: 78mm*165mm*42mm |
| CT Size | Φ128mm |
| Sampling Rate | 2 times/second |
| Measure Range | 0.00A~9999A(50/60Hz Auto Identification) |
| Resolution | 0.01A |
| Shift | 0.00A ~9999A Automatic Shift |
| Test Accuracy | ±2%rdg±5dgt(The wire is located near the center of the bottom of the u-type clamp, 23℃±2℃) |
| Position Error | The measured conductor should be located as close as possible to the
center of the top of the hook type clamp, and not close to the top of the u-type clamp. The test error on the top of the u-shaped clamp will increase by about one time or more |
| Data Storage | 99 sets, in storage process “MEM” symbol display, “FULL” symbol flash
indicate storage is full |
| Line Voltage | Below 110kV current test, operate with insulation rods (below 500kV
can be customized, only for GDCR9000B) |
| Data Hold | In general test mode, press HOLD key to hold data, “HOLD” symbol display. press HOLD Key once again to cancel this function |
| Data Access | “MR” symbol display, it can look over all the stored data |
| Overflow Display | Exceed measurement range overflow function: “OL A” symbol display |
| No signal Indication | When the receiver has not received transmit signal, dynamic display “no- -” symbol. |
| Auto Shut Down | About 15 minutes after booting up, the meter will shut down automatically without any operation, to decrease the battery consumption. |
| Battery Voltage | When the battery voltage is lower than 4.8V, the receiver display low battery voltage symbol “ ”(the detector low voltage display “ ” symbol, the receiver low voltage continue display), remind to replace battery. |
| Meter Weight | Detector: About 300g,
Receiver: 280g Total weight of meter: about 2300g (including insulation rod and battery.) |
| Working Temperature | -10°C~40°C; Below 80%RH |
| Storage Temperature | -10°C~60°C; Below 70%RH |
| Interference | Should avoid 315Mhz,433Mhz Same frequency signal interference |
| Insulation Rod Dimension | 4300mm |
| Insulation Strength | AC 110kV/rms (The telescopic insulation rod is fully opened between the two ends) |
| Structure | Anti-Dripping Type II |